Tomographic reconstruction using tilted Laue analyser-based X-ray phase-contrast imaging
dc.contributor.author | Chalmers MC | |
dc.contributor.author | Kitchen MJ | |
dc.contributor.author | Uesugi K | |
dc.contributor.author | Falzon G | |
dc.contributor.author | Quine P | |
dc.contributor.author | Pavlov, Konstantin | |
dc.date.accessioned | 2021-09-23T23:06:21Z | |
dc.date.available | 2021-09-23T23:06:21Z | |
dc.date.issued | 2021 | en |
dc.date.updated | 2021-07-02T23:28:13Z | |
dc.description.abstract | Analyser-based phase-contrast imaging (ABPCI) is a highly sensitive phase-contrast imaging method that produces high-contrast images of weakly absorbing materials. However, it is only sensitive to phase gradient components lying in the diffraction plane of the analyser crystal [i.e. in one dimension (1-D)]. In order to accurately account for and measure phase effects produced by the wavefield-sample interaction, ABPCI and other 1-D phase-sensitive methods must achieve 2-D phase gradient sensitivity. An inclined geometry method was applied to a Laue geometry setup for X-ray ABPCI through rotation of the detector and object about the optical axis. This allowed this traditionally 1-D phase-sensitive phase-contrast method to possess 2-D phase gradient sensitivity. Tomographic datasets were acquired over 360° of a multi-material phantom with the detector and sample tilted by 8°. The real and imaginary parts of the refractive index were reconstructed for the phantom. | en |
dc.identifier.citation | Chalmers MC, Kitchen MJ, Uesugi K, Falzon G, Quine P, Pavlova KM (2021). Tomographic reconstruction using tilted Laue analyser-based X-ray phase-contrast imaging. Journal of Synchrotron Radiation. 28(Pt 1). 283-291. | en |
dc.identifier.doi | http://doi.org/10.1107/S1600577520013995 | |
dc.identifier.issn | 0909-0495 | |
dc.identifier.issn | 1600-5775 | |
dc.identifier.uri | https://hdl.handle.net/10092/102553 | |
dc.language | eng | |
dc.language.iso | en | |
dc.publisher | International Union of Crystallography (IUCr) | en |
dc.rights | All rights reserved unless otherwise stated | en |
dc.rights.uri | http://hdl.handle.net/10092/17651 | en |
dc.subject | analyser-based imaging | en |
dc.subject | phase retrieval | en |
dc.subject | phase-contrast imaging | en |
dc.subject | phase-contrast tomography | en |
dc.subject.anzsrc | 0204 Condensed Matter Physics | en |
dc.subject.anzsrc | 0205 Optical Physics | en |
dc.subject.anzsrc | 0306 Physical Chemistry (incl. Structural) | en |
dc.subject.anzsrc | Fields of Research::51 - Physical sciences::5105 - Medical and biological physics | en |
dc.subject.anzsrc | Fields of Research::51 - Physical sciences::5102 - Atomic, molecular and optical physics | en |
dc.subject.anzsrc | Fields of Research::40 - Engineering::4003 - Biomedical engineering | en |
dc.title | Tomographic reconstruction using tilted Laue analyser-based X-ray phase-contrast imaging | en |
dc.type | Journal Article | en |
uc.college | Faculty of Science | |
uc.department | School of Physical & Chemical Sciences |
Files
Original bundle
1 - 1 of 1