Structural Health Monitoring using Adaptive LMS Filters
dc.contributor.author | Nayyerloo, M. | |
dc.contributor.author | Chase, Geoff | |
dc.contributor.author | MacRae, G.A. | |
dc.contributor.author | Chen, X.Q. | |
dc.contributor.author | Hann, C. | |
dc.date.accessioned | 2011-05-01T20:45:45Z | |
dc.date.available | 2011-05-01T20:45:45Z | |
dc.date.issued | 2010 | en |
dc.description.abstract | A structure’s level of damage is determined using a non-linear model-based method utilising a Bouc-Wen hysteretic model. It employs adaptive Least Mean Squares (LMS) filtering theory in real time to identify changes in stiffness due to modelling error damage, as well as plastic and permanent displacements, which are critical to determining ongoing safety and use. The Structural Health Monitoring (SHM) method is validated on a four-story shear structure model undergoing seismic excitation. For the simulated structure, the algorithm identifies stiffness changes to within 10% of the true value in 0.20 s, and permanent deflection is identified to within 5% of the actual as-modelled value using noise-free simulation-derived structural responses. | en |
dc.identifier.citation | Nayyerloo, M., Chase, J.G., MacRae, G.A., Chen, X.Q., Hann, C. (2010) Structural Health Monitoring using Adaptive LMS Filters. International Journal of Computer Applications in Technology (IJCAT), 39(1/2/3), pp. 130-136. | en |
dc.identifier.doi | https://doi.org/10.1504/IJCAT.2010.034741 | |
dc.identifier.issn | 0952-8091 | |
dc.identifier.uri | http://hdl.handle.net/10092/5159 | |
dc.language.iso | en | |
dc.publisher | University of Canterbury. Civil and Natural Resources Engineering | en |
dc.publisher | University of Canterbury. Electrical and Computer Engineering | en |
dc.publisher | University of Canterbury. Mechanical Engineering | en |
dc.rights.uri | https://hdl.handle.net/10092/17651 | en |
dc.subject | SHM | en |
dc.subject | structural health monitoring | en |
dc.subject | adaptive filtering | en |
dc.subject | LMS | en |
dc.subject | least mean squares | en |
dc.subject | Bouc-Wen model | en |
dc.subject | damage detection | en |
dc.subject | non-linear structure | en |
dc.subject | computer vision | en |
dc.subject | line scan camera | en |
dc.subject.anzsrc | Fields of Research::40 - Engineering::4005 - Civil engineering::400506 - Earthquake engineering | en |
dc.subject.anzsrc | Fields of Research::40 - Engineering::4005 - Civil engineering::400510 - Structural engineering | en |
dc.title | Structural Health Monitoring using Adaptive LMS Filters | en |
dc.type | Journal Article |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 12625420_IJCAT19_Nayyerloo et al.pdf
- Size:
- 420.01 KB
- Format:
- Adobe Portable Document Format