Fire Design of Single Storey Industrial Buildings (1996)

Degree Name
Research ReportPublisher
University of Canterbury. Civil EngineeringCollections
- Engineering: Reports [740]
Abstract
This report aims to establish a design methodology for meeting basic fire safety objectives within single storey industrial buildings using a 'common-sense' approach. A wide range of fire safety issues are addressed, ranging from environmental protection to life safety and structural performance. The emphasis is on meeting the performance requirements of the New Zealand Building Code for fire safety and hazard management. Given that industrial buildings are likely to fall into a high fire hazard category, alternative fire engineering design methods are deemed necessary for Building Code compliance. Attention is also given to issues that are not part of Building Code requirements or acceptable solutions. A fire safety strategy is recommended for an industrial site, with the focus on establishing a level of 'acceptable loss'. A risk assessment provides the means to meet loss control objectives. This should form the basis for a new buildings' fire protection design, plus the on-going fire safety management programme. Automatic alarms are considered essential for life safety and property protection, with sprinklers being the only method of controlling a fire within a typical industrial complex. The Fire Service cannot be expected to attack and suppress a fire from receiving an alarm call without sprinkler support. The Fire Service can, however, be expected to control the spread of fire to neighbouring property given certain conditional events work in their favour. The act of prewetting neighbouring combustible surfaces and thereby increasing the critical radiation intensity for pilot ignition, is considered very effective in preventing fire spread. Increasing fire rating requirements for boundary walls based on withstanding equivalent fire severities for the 'design' fire, is considered overly conservative. A maximum rating of 4 hours is recommended for any boundary wall. This recommendation is based on maximum values used in overseas Codes and assumes that boundary walls are connected to primary support structures and adjoining wall panels, so that if they fail they collapse inwards as one complete unit. The report provides a comprehensive list of conclusions that expand on the above overview, plus recommends areas for future research.
ANZSRC Fields of Research
40 - Engineering::4005 - Civil engineering::400510 - Structural engineering09 - Engineering::0905 - Civil Engineering::090599 - Civil Engineering not elsewhere classified
Rights
Copyright B W CosgroveRelated items
Showing items related by title, author, creator and subject.
-
Spalling of concrete: Implications for structural performance in fire
Deeny, S.; Stratford, T.; Dhakal, Rajesh; Moss, P.J.; Buchanan, A.H. (University of Canterbury. Civil and Natural Resources Engineering, 2008)This preliminary paper is a progress report on an analytical investigation into the implications of explosive spalling on the fire performance of reinforced concrete structural elements and whole structures. This study ... -
Fire Resistance of Prestressed Concrete
Griffin, Mike; Beavis, Brian (University of Canterbury. Civil Engineering, 1992)In summary some general comments can be made about prestressed concrete in fire. The main problem is the amount of cover required to protect the steel from reaching excessive temperatures. This is also the main problem ... -
Verification of code fire ratings of precast prestressed concrete slabs
Min, J-K.; Abu, A.K.; Moss, P.J.; Dhakal, Rajesh; Buchanan, A.H. (University of Canterbury. Civil and Natural Resources Engineering, 2012)In fire design for floors, the three criteria of stability, integrity and insulation are required for the specified fire resistance duration. Among these, stability is not easy to confirm. For solid prestressed concrete ...