Application of Floor Isolation Systems for Multi-functional Seismic Mitigation: Computational Results

dc.contributor.authorHarvey, P. Scott Jr.
dc.contributor.authorSenarathna, Nisal Halaba Arachchige
dc.contributor.authorCalhoun, Skylar J.
dc.date.accessioned2016-09-26T20:49:28Z
dc.date.available2016-09-26T20:49:28Z
dc.date.issued2016en
dc.description.abstractVibration-sensitive equipment within buildings may be susceptible to damage from harsh floor motions transmitted from the primary structure due to strong ground motions. Isolation devices are capable protecting fragile equipment from seismic hazards by decoupling individual pieces of equipment or entire floor slabs. A practical limitation associated with equipment isolation is that these systems have limited displacement capacity, which if exceeded lead to impacts degrading performance. However, even the most e ective isolation systems are incapable of protecting equipment from building collapse. This study investigates the use of floor isolation systems (FISs) as multi-functional structural units to mitigate both equipment accelerations and structure responses to achieve desired building-system performance. These multi-functional FISs not only serve their traditional purpose (equipment isolation), but they are also engaged to protect the primary structure under extreme earthquake loads by passively adapting to function as nonlinear dynamic vibration absorbers. In so doing, this concept bridges the gap between equipment isolation and vibration absorption, yielding a novel adaptive passive seismic protective technique. Simulation results indicate that multi-functional FIS can reduce equipment accelerations for small to moderate earthquakes, as well as deflections (drifts) of the primary building over a range of disturbance intensities. Overall, multi-functional FISs are shown to enhance building-system resilience over a broad range of seismic hazard levels.en
dc.identifier.urihttp://hdl.handle.net/10092/12783
dc.language.isoen
dc.publisherQuake CoREen
dc.rightsCC-BY 4.0 Internationalen
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/legalcode
dc.titleApplication of Floor Isolation Systems for Multi-functional Seismic Mitigation: Computational Resultsen
dc.typeConference Contributions - Other
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
POSTER - Harvey_FlrIslationSystmsCmpuResults_QCAM_2016.pdf
Size:
968.04 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: