dc.description.abstractAn analytical method based on the theory and experimental techniques of differential scanning calorimeter is proposed to investigate the determination of the heat of reaction for wood in experiments with and without crucible lids. It is found that the heat exchange dynamics are different for the two cases during decomposition which causes the rate of energy transfer to differ and the values of heat of reaction to vary quantitatively. However, these results still demonstrate consistent energy absorbing and releasing behaviour during the decomposition process in both lid scenarios. In addition, the quantitative differences for the heat of reaction only have a weak effect on the predictions of burning behaviour for cone calorimeter simulations in Fire Dynamics Simulator.en
dc.identifier.citationWang, X., Fleischmann, C., Spearpoint, M. (2015) The effect of using lids in differential scanning calorimeter experiments for determining the heat of reaction of wood. Coimbra, Portugal: 2015 International Fire Safety Symposium (IFireSS), 20-22 Apr 2015.en
dc.identifier.urihttp://hdl.handle.net/10092/11012
dc.language.isoen
dc.publisherUniversity of Canterbury. Civil and Natural Resources Engineeringen
dc.rights.urihttps://hdl.handle.net/10092/17651en
dc.subjectwood pyrolysisen
dc.subjectheat of reactionen
dc.subjectcrucible lidsen
dc.subjectDSCen
dc.subject.anzsrcFields of Research::34 - Chemical sciences::3406 - Physical chemistry::340602 - Chemical thermodynamics and energeticsen
dc.titleThe effect of using lids in differential scanning calorimeter experiments for determining the heat of reaction of wooden
dc.typeConference Contributions - Published
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
12655174_The effect of using lids in differential scanning calorimeter experiments for determining the heat of reaction of wood (final).pdf
Size:
947.19 KB
Format:
Adobe Portable Document Format