Accurate end systole detection in dicrotic notch-less arterial pressure waveforms.

dc.contributor.authorBalmer J
dc.contributor.authorSmith R
dc.contributor.authorPretty CG
dc.contributor.authorDesaive T
dc.contributor.authorShaw, Geoff
dc.contributor.authorChase, Geoff
dc.date.accessioned2020-03-25T01:47:01Z
dc.date.available2020-03-25T01:47:01Z
dc.date.issued2020en
dc.date.updated2020-02-23T20:15:26Z
dc.description.abstractIdentification of end systole is often necessary when studying events specific to systole or diastole, for example, models that estimate cardiac function and systolic time intervals like left ventricular ejection duration. In proximal arterial pressure waveforms, such as from the aorta, the dicrotic notch marks this transition from systole to diastole. However, distal arterial pressure measures are more common in a clinical setting, typically containing no dicrotic notch. This study defines a new end systole detection algorithm, for dicrotic notch-less arterial waveforms. The new algorithm utilises the beta distribution probability density function as a weighting function, which is adaptive based on previous heartbeats end systole locations. Its accuracy is compared with an existing end systole estimation method, on dicrotic notch-less distal pressure waveforms. Because there are no dicrotic notches defining end systole, validating which method performed better is more difficult. Thus, a validation method is developed using dicrotic notch locations from simultaneously measured aortic pressure, forward projected by pulse transit time (PTT) to the more distal pressure signal. Systolic durations, estimated by each of the end systole estimates, are then compared to the validation systolic duration provided by the PTT based end systole point. Data comes from ten pigs, across two protocols testing the algorithms under different hemodynamic states. The resulting mean difference ± limits of agreement between measured and estimated systolic duration, of [Formula: see text] versus [Formula: see text], for the new and existing algorithms respectively, indicate the new algorithms superiority.en
dc.identifier.citationBalmer J, Smith R, Pretty CG, Desaive T, Shaw GM, Chase JG (2020). Accurate end systole detection in dicrotic notch-less arterial pressure waveforms.. Journal of clinical monitoring and computing.en
dc.identifier.doihttps://doi.org/10.1007/s10877-020-00473-3
dc.identifier.issn1387-1307
dc.identifier.issn1573-2614
dc.identifier.urihttps://hdl.handle.net/10092/100052
dc.languageEnglish
dc.language.isoen
dc.publisherSpringer Science and Business Media LLCen
dc.subjectCardiovascular systemen
dc.subjectDicrotic notchen
dc.subjectEnd systoleen
dc.subjectPressure contour interpretationen
dc.subjectStart diastoleen
dc.subject.anzsrcField of Research::09 - Engineering::0903 - Biomedical Engineeringen
dc.subject.anzsrcFields of Research::32 - Biomedical and clinical sciences::3201 - Cardiovascular medicine and haematology::320101 - Cardiology (incl. cardiovascular diseases)en
dc.titleAccurate end systole detection in dicrotic notch-less arterial pressure waveforms.en
dc.typeJournal Articleen
uc.collegeFaculty of Engineering
uc.departmentMechanical Engineering
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
JCMC_dicrotic_notch-less_end_systole_detection.pdf
Size:
912.66 KB
Format:
Adobe Portable Document Format
Description:
Accepted version