Column Base Weak Axis Aligned Asymmetric Friction Connection Cyclic Performance

dc.contributor.authorBorzouie, J.
dc.contributor.authorMacRae, G.A.
dc.contributor.authorChase, Geoff
dc.contributor.authorRodgers, G.W.
dc.contributor.authorClifton, G.C.
dc.date.accessioned2015-09-28T23:10:48Z
dc.date.available2015-09-28T23:10:48Z
dc.date.issued2015en
dc.description.abstractRecent low damage studies have been made on beam-to-column joints and braces. However, if there is significant yielding damage at the column bases, even with no upper structure damage, then the whole structure may need replacement. Therefore, there is a need to develop low damage base connections. This paper presents experimental tests of columns connected to base plate by weak axis aligned asymmetric friction connection (WAFC base) to evaluate if it performs as a low damage connection. Cyclic tests are conducted in-plane about the strong axis, and out-of-plane with and without applied axial force to drift ratios as high as 4%. Observations from the experimental tests demonstrate that this type of base connection can tolerate high levels of drift without any significant damage at the base. Some flange compressive yielding occurs especially when the column was subjected to axial force. Generally, no major damage happened which interrupt the performance of the column and the base connection, and it can be categorized as a low-damage connection. Also, the presented analytical model for estimation of WAFC performance provides a reasonable estimation of the experimental results.en
dc.identifier.citationBorzouie, J., MacRae, G.A., Chase, J.G., Rodgers, G.W., Clifton, G.C. (2015) Column Base Weak Axis Aligned Asymmetric Friction Connection Cyclic Performance. Shanghai, China: 8th International Conference on Behavior of Steel Structures in Seismic Areas (STESSA 2015), 1-4 Jul 2015. 8pp.en
dc.identifier.urihttp://hdl.handle.net/10092/11000
dc.language.isoen
dc.publisherUniversity of Canterbury. Civil and Natural Resources Engineeringen
dc.publisherUniversity of Canterbury. Mechanical Engineeringen
dc.rights.urihttps://hdl.handle.net/10092/17651en
dc.subjectAsymmetric Friction Connection,en
dc.subjectWAFCen
dc.subjectLow Damage Designen
dc.subject.anzsrcFields of Research::40 - Engineering::4005 - Civil engineering::400510 - Structural engineeringen
dc.subject.anzsrcFields of Research::40 - Engineering::4005 - Civil engineering::400506 - Earthquake engineeringen
dc.titleColumn Base Weak Axis Aligned Asymmetric Friction Connection Cyclic Performanceen
dc.typeConference Contributions - Published