    Model Based Insulin Sensitivity As A Metabolic Marker For Sepsis In The ICU

    Thumbnail
    View/Open
    12612125_Chase.pdf (132.5Kb)
    Author
    Parente, J.
    Razak, N.
    Lin, J.
    Pretty, C.G.
    Chase, J.G.
    Shaw, G.M.
    Date
    2008
    Permanent Link
    http://hdl.handle.net/10092/2434

    Introduction: Severe sepsis and septic shock occur frequently in the Intensive Care Unit (ICU) and are a leading cause of admission, mortality and cost. Around 11-12% of all NZ and US ICU admissions are due to the more extreme cases of severe sepsis. Currently, the diagnosis of sepsis presents many challenges in a clinical setting. Sepsis treatment consists of antibiotic therapy with the use of fluid therapy and vasopressors. A positive blood culture for the specific sepsis type should precede the use of antibiotics and other therapies. Importantly, many of these therapies would be contra-indicated if sepsis wasn’t present. However, such blood culture results take 24-48 hours to process, by which time the disease may be advanced and more difficult to treat. Faster approximate diagnoses can be obtained in 4-8 hours using a variety of biomarkers, but with highly variable success. As a result, physicians often prescribe broad-based antibiotic and other therapy based on inconclusive data as a pre-emptive attack on the possibility of sepsis. A model-based insulin sensitivity was found to decrease with worsening condition and could thus be used to aid diagnosis.

    Methods: Using a validated insulin-glucose regulatory mathematical model, the modelled insulin sensitivity (SI) is evaluated against clinical sepsis diagnosis for 394 ICU patients (totaling 26,453 patient hours) who were on a glycemic control protocol. Patients with type I or type II diabetes were excluded. Ethics approval for this study was granted by the South Island Regional Ethics Committee. Receiver operating characteristic curve is calculated. A cutoff value for insulin sensitivity is determined, over which sepsis is unlikely to occur. Negative and positive predictor values are calculated. Correlation between model-based insulin sensitivity and sepsis score (ss) is calculated (ss = 0–4 for increasing severity). A simple sepsis indicator score (SSI) which can be calculated from a patient’s feed and insulin history at the bedside is developed to reflect model-based insulin sensitivity. This score is retrospectively tested against the 394 ICU patient’s sepsis diagnosis.

    Results: Receiver operating characteristic cutoff values of SI = 8 × 10-5 L/mU/min and SSI = 2.8 × 10-4 L/mU/min were determined for ss = 3. The model-based SI fell below this value in 15% of all patient hours. The SI test had a negative predictive value of 99.8%. The test sensitivity was 78% and specificity was 82%. Slightly lower sensitivity (68.8%) and specificity (81.7%), but equally good negative prediction (99.7%), were obtained for SSI.

    Discussion: Model-based insulin sensitivity value provides an accurate negative predictive diagnostic for sepsis. The positive predictor value may be further improved by a more specific clinical symptom filter. Higher insulin sensitivity rules out sepsis for the majority of patient hours and can be determined noninvasively from glycemic control protocol data. Real-time indicator SSI can be quickly calculated by the bedsides and aid the decision on antibiotics usage. Clinical measurements such as blood pressure and heart rate derivatives may be further examined to enhance the accuracy of SSI. Low insulin sensitivity is not a sufficiently effective diagnostic, as it can equally mark the presence of sepsis or other conditions. Combining insulin sensitivity and other clinical measurements and medication history may lead to a better indicator for sepsis.

    Conclusions: The use of model-based insulin sensitivity provides a non-invasive and quick indicator for the diagnostic of sepsis. Higher insulin sensitivity indicates the unlikelihood of sepsis, and thus prevents unnecessary antibiotic usage and the possibility of antibiotics resistance. Lower insulin sensitivity can be brought on by sepsis as well as a range of other conditions. Further study of clinical measurements and medication history may improve the accuracy of a sepsis indicator.

    Subjects
    Fields of Research::320000 Medical and Health Sciences::321000 Clinical Sciences::321004 Endocrinology
     
    Fields of Research::320000 Medical and Health Sciences::321000 Clinical Sciences::321009 Intensive care
     
    Fields of Research::290000 Engineering and Technology::291500 Biomedical Engineering::291504 Biomechanical engineering
    Collections
    • Engineering: Conference Contributions [1920]
    Rights
    https://canterbury.libguides.com/rights/ir

    UC Research Repository
    University Library
    University of Canterbury
    Private Bag 4800
    Christchurch 8140

    Phone
    364 2987 ext 8718

    Email
    ucresearchrepository@canterbury.ac.nz

    Follow us
    FacebookTwitterYoutube

    © University of Canterbury Library
    Send Feedback | Contact Us