    Conceptual retrofit strategy for existing hollowcore seating connections

    Thumbnail
    View/Open
    12605038_Main.pdf (1.140Mb)
    Author
    Jensen, J.P.
    Bull, D.K.
    Pampanin, S.
    Date
    2006
    Permanent Link
    http://hdl.handle.net/10092/193

    Previous research regarding the seismic performance of existing precast hollowcore floor and ductile lateral frame systems has highlighted several behavioural uncertainties. In particular poor seismic performance due to deformation incompatibilities between the floor diaphragm and frame seismic resisting system have become apparent. Significant rotation and displacement demand on the floor systems due to frame beam elongation, seating beam rotation, and longitudinal perimeter vertical displacement have been identified as the main sources of undesirable damage. As a result the structural integrity at hollowcore seating and perimeter connection interfaces can be jeopardised, potentially leading to a partial or even complete floor collapse. In this paper an overview of expected compatibility issues is given while providing suggestions for conceptual low-invasive retrofit strategies. Particular focus will be given to the experimental investigation on the vulnerability of and suggested retrofit solutions for hollow core-seating connections. The Quasi-static experimental testing procedure focusing on a series of as-built and retrofitted specimens, reproducing a hollowcore-toseating- beam connection with traditionally adopted details will be presented. Both seating rotation due to the imposed lateral drift and beam elongation effects are simulated in the applied testing set-up. Simplified analysis and modelling aspects regarding the connection behaviour are discussed; expected damage and performance criteria associated with the alternative existing or retrofit solution are also tentatively indicated.

    Subjects
    Fields of Research::290000 Engineering and Technology::290800 Civil Engineering::290801 Structural engineering
    Collections
    • Engineering: Conference Contributions [1816]
    Rights
    http://library.canterbury.ac.nz/ir/rights.shtml

    UC Research Repository
    University Library
    University of Canterbury
    Private Bag 4800
    Christchurch 8140

    Phone
    364 2987 ext 8718

    Email
    ucresearchrepository@canterbury.ac.nz

    Follow us
    FacebookTwitterYoutube

    © University of Canterbury Library
    Send Feedback | Contact Us